Gas boiler goes out or will not light: what to check and what to tell the technician

A boiler that goes out in the middle of a shower or will not start the heating in the morning usually has one of a few known causes, and you can check some of them before you call.

7 min readUpdated 23/11/2026Mendkin

When a gas boiler goes out or will not light, first check three things yourself: is the gas valve open and do other gas appliances work, does the boiler have power, and is the water pressure on the gauge within the range in the manual. If all is in order, write down the fault code and press the reset button once. For its code F28, Vaillant writes that no flame signal was detected during the ignition phase, and lists closed gas, low gas pressure, a blocked flue or condensate drain, a frozen condensate pipe and faulty ignition parts as causes. If the fault comes back, do not keep resetting; call an authorised technician. If you smell gas, close the gas, open the windows, do not touch switches and call the gas distributor's emergency service from outside. In the request, give the make, model and year of the boiler and the fault code.

What should I check before calling a technician?

Gas, power and water pressure, in that order. These three checks need no tools and no opening of the casing, and they often reveal a cause the technician does not have to fix.

Write down every check, including the ones that were fine. A technician who knows what has already been checked gets to the real cause faster.

  1. Check that the handle of the gas valve under the boiler is in the open position, along the pipe.

  2. Check whether the hob or other gas appliances work, if you have them.

  3. Check that the boiler display is lit and that the fuse in the consumer unit is on.

  4. Read the water pressure on the gauge and compare it with the range in the boiler manual.

  5. Write down the fault code or the light that is flashing on the display.

If you smell gas, do none of this. Close the gas, open the windows, do not switch lights or appliances on or off, and call the gas distributor's emergency service from outside.

What does an ignition fault code on the display mean?

That the boiler could not light the flame or lost it while running. Every manufacturer has its own codes, so look up the meaning in the manual for your model.

For example, Vaillant writes on its website that code F28 means an ignition fault, and the official description is that no flame signal was detected during the ignition phase. With the same manufacturer, code F29 means that relighting after the flame was lost during operation did not succeed.

Always copy the code exactly as it appears on the display, with or without a dot. Other makes use other letters and numbers for a similar fault.

What are the most common causes when the boiler will not light?

No gas, gas pressure that is too low, a blocked flue or condensate drain, and faulty ignition parts. The first two lie outside the boiler, the rest inside it.

For code F28, Vaillant also lists air in the gas supply, most often after the boiler is first put into service, and a frozen condensate pipe on condensing boilers. A faulty ignition electrode, burner or control board can also be the cause.

CauseWho fixes it
Gas valve closedyou, by opening the valve
No gas in the whole housethe gas distributor
Boiler has no poweryou or an electrician
Frozen condensate pipethe technician, or you following the manufacturer's instructions
Blocked flue or condensate drainan authorised technician
Electrode, burner, gas valve, control boardan authorised technician

Why does the boiler go out while it is running?

Most often because it loses the flame, overheats or its water pressure drops. The boiler then stops by itself and shows a fault code.

If it goes out only when it heats water for a long time, the cause may be the water flow or overheating. If it also goes out when it is cold outside and it is a condensing model, check whether the outside condensate pipe is frozen.

Write down when it goes out: right after lighting, after a few minutes, or only with hot water. That is usually the first thing the technician asks.

May I reset the boiler myself?

Once, yes, with the reset button described in the manual. If the same fault comes back, do not keep resetting it, because that does not remove the cause.

For fault F28, Vaillant states plainly that this is a case for a professional and that you should not try to solve it yourself. The casing, the gas valve and the ignition parts are opened and replaced only by an authorised technician.

Repeated resets with the gas closed or the flue blocked do not help, and they hide something the technician needs to know: how many times the fault has appeared.

What should I do when the system water pressure drops?

Top the system up to the value in the manual and watch the pressure for a few days. If it drops again, water is leaking somewhere and a tradesperson should look at it.

The filling valve is on the boiler or next to it. Open it slowly while watching the gauge, and close it as soon as the pressure is within the stated range. How radiators are bled, and why the pressure then drops, is explained in the guide on heating before winter.

How much does a gas boiler service cost?

Published prices for a regular service run from about eighty euros for an instantaneous water heater to about 175 euros for a combi boiler. Repairs and parts are charged separately.

The figures below come from one service company's published price list. All items, with the date they were read, are on gas boiler service, and other prices in the trade are on plumber prices.

JobPublished price
Service of an instantaneous gas water heater (Plinoservis Malović)€85, source does not state VAT
Service of a combi gas boiler (Plinoservis Malović)€175, source does not state VAT

How do I stop the fault from coming back?

With a regular yearly service before the heating season and a clear flue. At the service the burner and heat exchanger are cleaned and the ignition parts are checked.

Do not close the air vents in the room with the boiler, and do not put anything over the outside end of the flue. On a condensing boiler, the outside condensate pipe should be protected from freezing.

Keep the service booklet or the invoice for the last service next to the boiler, together with the manual. That way you know when the next service is due, and the technician knows what has been replaced.

What should I write in the request to the technician?

The make, model and year of the boiler, the fault code, when it goes out and what you have already checked. With that, the technician knows which parts to bring.

A photo of the rating plate and a photo of the display showing the fault replace several messages. Providers for water and heating are on plumber, and how to describe the job so quotes can be compared is shown on the quote form.

  1. Make, model and year of the boiler from the rating plate.

  2. The fault code exactly as it appears on the display.

  3. When it goes out: on lighting, after a few minutes, or only with hot water.

  4. What you have checked: gas, power, water pressure.

  5. Date of the last service, if you know it.

Questions

Why will the gas boiler not light after a power cut?

One reset with the button from the manual is often enough. If the fault comes back, call a technician and say it appeared after the power cut.

What does F28 mean on a Vaillant boiler?

An ignition fault: according to the manufacturer, no flame signal was detected during the ignition phase.

How many times may I reset the boiler?

Once. If the same fault returns, the cause is still there and a technician needs to find it.

Why does the boiler go out when it is very cold outside?

On condensing boilers the outside condensate pipe can freeze and stop the boiler.

What should I do if I smell gas?

Close the gas, open the windows, do not touch switches, and call the gas distributor's emergency service from outside.